Detecting
FBS1100-0900
SENSOR WITH BINARY INPUT SINGLE
For connecting sensors like light barriers, twilight switches on TCS front-door stations. For transmitting additional switching functions, e.g. garage doors and shutter controls in conjunction with BRE-xx. The sensor is not compatible with systems for assisted living or with special call function.
- Input differentiates between opening and closing as well as the duration of the keystroke
- Input requires connection of a potential-free switch
- 2- or 3-wire technique possible
- Maximum 10 devices usable with 2-wire technique
- Input current (binary input): 0.4mA (use appropriate contacts)
- Input current (2-wire): I(a) = 1.3mA (input not activated)
- Input current (3-wire): I(a) = 0.4mA, I(P) = 1.0mA without load
- Max. input current (2-wire): I(a) = 1.7mA (input activated)
- Max. input current (3-wire): I(a) = 2.3mA (input activated)
- Maximum length of input connecting line: 2m
- Integrated connecting line with 8 cm, length, 0.8mm diameter
- Acceptable ambient temperature: -20°C to 50°C
- Degree of protection: IP20 (installation in one gang box, protection against moisture)
BMN2-EB
SENSOR WITH BINARY INPUT DOUBLE (FM)
Input for triggering control functions, double
- Input differentiates between opening and closing
- Input requires connection of a potential-free switch
- 2- or 3-wire technique possible
- For use in systems for assisted living | with special call function
- Maximum 10 devices usable with 2-wire technique
- Input current (binary input): 0.4mA (use suitable contacts)
- Input current (2-wire): I(a) = 1.1mA without load
- Max. input current (2-wire):I(a) = 2.5mA (both inputs activated)
- Maximum length of input connecting line: 2m
- Max. line diameter: 0.8mm
- Acceptable ambient temperature: -20°C to 50°C
- Degree of protection: IP20 (installation in one gang box, protection against moisture)
FBS1105-0900
BUILT-IN DOOR RELEASE TRANSMITTER
Configurable sensor for triggering a function on TCS:BUS
- Input for triggering door release, floor call, light and control functions
- Input differentiates between opening and closing
- Input requires connection of a potential-free switch
- 2- or 3-wire technique possible
- Configuration with configuration software configo (starting with version 1.6)
- Not for use in systems with special call functions
- Maximum 10 devices usable with 2-wire technique
- Input current (binary input): (0.4mA) use appropriate contacts
- Input current (2-wire): I(a) = 1.3mA (input not activated)
- Input current (3-wire): I(a) = 0.4mA, I(P) = 1.0mA without load
- Max. input current (2-wire): I(a) = 1.7mA without load
- Max. input current (3-wire): I(a) = 1.5mA (input activated)
- Maximum length of input connecting line: 2m
- Integrated connecting lines with 8cm length, 0.8mm diameter
- Acceptable ambient temperature: -20°C to 50°C
- Degree of protection: IP64 (for installation in one gang box)
FIS1100-0600
FLOOR CALL GENERATOR
For up to 4 floor calls
- 1 TCS:BUS protocol programmable per channel
- Supply of the module via TCS:BUS in 3-wire technique (loop through possible)
- Can be used multiple times on one floor
- Programming mode can be switched on directly on the device
- Indication of the operation mode by yellow LED
- Call distinction
- Supply voltage: 26V DC ± 8 %
- Supply output: (2mA)
- Acceptable ambient temperature: -20°C to 50°C
Article numbers
Description | H x W x D in mm | Article number |
---|---|---|
Sensor mit Binäreingang 1-fach | H 17 x B 26 x T 8 mm | FBS1100-0900 |
Sensor mit Binäreingang 2-fach, UP | H 52 x B 52 x T 23 mm | BMN2-EB |
Einbau-Türöffnersender 1-fach | H 17 x B 26 x T 8 mm | FBS1105-0900 |
Etagenruf-Generator für bis zu 4 Etagenrufe | H 52 x B 52 x T 23 mm | FIS1100-0600 |
Downloads
Product data sheet FBS1100 | |
Product data sheet BMN2-EB | |
Product data sheet FBS1105 | |
Product data sheet FIS1100 |