Detecting

FBS1100-0900
SENSOR WITH BINARY INPUT SINGLE

For connecting sensors like light barriers, twilight switches on TCS front-door stations. For transmitting additional switching functions, e.g. garage doors and shutter controls in conjunction with BRE-xx. The sensor is not compatible with systems for assisted living or with special call function.

  • Input differentiates between opening and closing as well as the duration of the keystroke
  • Input requires connection of a potential-free switch
  • 2- or 3-wire technique possible
  • Maximum 10 devices usable with 2-wire technique
  • Input current (binary input): 0.4mA (use appropriate contacts)
  • Input current (2-wire): I(a) = 1.3mA (input not activated)
  • Input current (3-wire): I(a) = 0.4mA, I(P) = 1.0mA without load
  • Max. input current (2-wire): I(a) = 1.7mA (input activated)
  • Max. input current (3-wire): I(a) = 2.3mA (input activated)
  • Maximum length of input connecting line: 2m
  • Integrated connecting line with 8 cm, length, 0.8mm diameter
  • Acceptable ambient temperature: -20°C to 50°C
  • Degree of protection: IP20 (installation in one gang box, protection against moisture)

BMN2-EB
SENSOR WITH BINARY INPUT DOUBLE (FM)

Input for triggering control functions, double

  • Input differentiates between opening and closing
  • Input requires connection of a potential-free switch
  • 2- or 3-wire technique possible
  • For use in systems for assisted living | with special call function
  • Maximum 10 devices usable with 2-wire technique
  • Input current (binary input): 0.4mA (use suitable contacts)
  • Input current (2-wire): I(a) = 1.1mA without load
  • Max. input current (2-wire):I(a) = 2.5mA (both inputs activated)
  • Maximum length of input connecting line: 2m
  • Max. line diameter: 0.8mm
  • Acceptable ambient temperature: -20°C to 50°C
  • Degree of protection: IP20 (installation in one gang box, protection against moisture)

FBS1105-0900
BUILT-IN DOOR RELEASE TRANSMITTER

Configurable sensor for triggering a function on TCS:BUS

  • Input for triggering door release, floor call, light and control functions
  • Input differentiates between opening and closing
  • Input requires connection of a potential-free switch
  • 2- or 3-wire technique possible
  • Configuration with configuration software configo (starting with version 1.6)
  • Not for use in systems with special call functions
  • Maximum 10 devices usable with 2-wire technique
  • Input current (binary input): (0.4mA) use appropriate contacts
  • Input current (2-wire): I(a) = 1.3mA (input not activated)
  • Input current (3-wire): I(a) = 0.4mA, I(P) = 1.0mA without load
  • Max. input current (2-wire): I(a) = 1.7mA without load
  • Max. input current (3-wire): I(a) = 1.5mA (input activated)
  • Maximum length of input connecting line: 2m
  • Integrated connecting lines with 8cm length, 0.8mm diameter
  • Acceptable ambient temperature: -20°C to 50°C
  • Degree of protection: IP64 (for installation in one gang box)

FIS1100-0600
FLOOR CALL GENERATOR

For up to 4 floor calls

  • 1 TCS:BUS protocol programmable per channel
  • Supply of the module via TCS:BUS in 3-wire technique (loop through possible)
  • Can be used multiple times on one floor
  • Programming mode can be switched on directly on the device
  • Indication of the operation mode by yellow LED
  • Call distinction
  • Supply voltage: 26V DC ± 8 %
  • Supply output: (2mA)
  • Acceptable ambient temperature: -20°C to 50°C

 

Article numbers

Description H x W x D in mm Article number
Sensor mit Binäreingang 1-fach H 17 x B 26 x T 8 mm FBS1100-0900
Sensor mit Binäreingang 2-fach, UP H 52 x B 52 x T 23 mm BMN2-EB
Einbau-Türöffnersender 1-fach H 17 x B 26 x T 8 mm FBS1105-0900
Etagenruf-Generator für bis zu 4 Etagenrufe H 52 x B 52 x T 23 mm FIS1100-0600

Unsere Produkte

Alle Produkte

Unsere Anwendungen

Alle Anwendungen