Switching and detecting
BRE2-SG
COMBINED DEVICE WITH BINARY IN/OUT
Output for switching functions and input for triggering control functions
- Input differentiates between opening and closing
- Input requires connection of a potential-free switch
- Potential-free relay contact (closing contact: 230V, 50/60Hz/3A)
- Features that cannot be changed without auxiliary means:
- Switch time ex works: 1s/manually and with BRE configurator adjustable
- Triggering the switch time by: bell button of any front-door station, floor push-button/door release button on any indoor station
- Input current (binary input): (2.5mA)
- Input current (3-wire): I(a) = 0.4mA, I(P) = 1.4mA without load
- Max. input current: I(Pmax) = 30mA
- Max. line diameter: 1.4mm
- Parameter can be adjusted with BRE-configurator
- 3-wire technique required
- Acceptable ambient temperature:-20°C to 50°C
- Status indication for input / output
BRE2-EB
COMBINED DEVICE WITH BINARY IN/OUT
Features like BRE-SG, deviating from that:
- Input current (2-wire): I(a) = 1.5mA without load
- Input current (3-wire): I(a) = 0.4mA, I(P) = 2.8mA without load
- Max. input current (3-wire): I(Pmax) = 4.4mA
- Maximum line diameter: 0.8mm (M+, M-, A-, B-, P-terminal)
- Acceptable ambient temperature: -20°C to 50°C
Article numbers
Description | H x W x D in mm | Article number |
---|---|---|
Kombi-Gerät mit Binärein-/ausgang | H 85 x B 17,5 x T 60 mm (1 TE) | BRE2-SG |
Kombi-Gerät mit Binärein-/ausgang | H 52 x B 52 x T 23 mm | BRE2-EB |